Quantity (piece) | 1 - 100 | > 100 |
Lead time (days) | 10 | To be negotiated |
Sold By: GEM LİFT ASANSÖR
PRODUCT NAME: LIFT CONTROLLER HD EKO 10
BRAND: HEDEFSAN
GENERAL INFORMATION:
Internal Phase Protection
10 Stops Stable Working
Internal Automatic Door Relay
GENERAL SPECIFICATION:
• Supports up to 10 fIoors, options between a up or down collective or full coIIectIve control
• Includes an otomatic door controller.
• Cali buttons and lamps require only one shared wire.
• Simple and error fee installation due to included terminals. Economlcal and Time saving.
• Cabin serial communication output.
• All parameters can easily be configured via LCD screen and keyboard buttons.
• Adjustable parking station and travelling time
• At the waiting position, you can trace down and read off how long the lift worked after it's last maintenance via the LCD screen
• Programming with password protection code protection against unauthorized using
• Position Information by Pulse bi-stable switches
• Adjustable maintenance time, and warning on LCD screen when maintenance is required
• The function of manual movement at low speed by using program buttons.
• Short circuit protected display outputs can be adjusted to every floor.
• For lifts that have only one fully automatic door the floor of the position of the automatic door can be chosen,
• The display outputs are changeable to gray-code or binary outputs
• Overfoad warning signal
• At Inspection the movement to limit switches or exact floor level can be chosen.
• Adjustable car lamp time lock wait time, wait at floor time, max high speed time and max low speed time
• Outputs for direction arrows, Out Of Service signal and busy signal via 5A relay, a signal common input for these outputs
• Related to request when power returns after a power loss, the car moves to the first floor
• Electronic control of phases, phase order and PTC (Motor temperature) errors of these controls shown via LCD on board, turning off function by choosing the parameters, adjustable phase level sensitivity,
• Warning signal on LCD screen when the door is open for a long time or when the stop return circuit is not detected for a long time